A record of every drinking-water sample, checked by where it was taken and by what's in it.
The sampler collects at the source, the lab tests the bottle, JalSatya compares the water with that source's own chemistry, and the division acts on anything that doesn't fit.
Four steps, three people
Today, and with JalSatya
What the Department asked for, and where to see it
| The challenge asks for | What JalSatya does | |
|---|---|---|
| Geo-fencing / GPS or equivalent location verification | Each source has a permitted area. The phone must be inside it, with GPS accuracy shown. Mock-location apps are detected. | See it |
| Secure source identification | A source ID from the JJM register, an optional QR plate, and the water's own fingerprint, which a copied plate can't fake. | See it |
| Timestamping and field evidence | Network time, an in-app photo of the bottle at the source, and a pocket-meter conductivity reading. | See it |
| Offline capture | The day's list and every sample are kept on the phone and sync when there's signal. | See it |
| Chain-of-custody tracking | QR bottles scanned at the source and at lab check-in, with time since collection and a second conductivity reading. No result without a check-in. | See it |
| Configurable blocking or flagging outside the permitted area | The AE sets, for each kind of source, the permitted radius and whether collection outside it is blocked or only flagged. | See it |
| Auditable exceptions for genuine field or GPS constraints | Reason codes, a note and an extra photo from the sampler; a decision with a reason from the AE. Kept with the sample for good. | See it |
| GIS | A division map of sources with predicted arsenic, fluoride and iron risk, and which have never been tested. | See it |
| Anomaly detection | The fingerprint check on every result, conductivity at both ends, and second-sample agreement by team. | See it |
| AI / analytics on historical results: recurring failures, seasonal trends, deterioration, emerging risks | Source profiles with trends where there's enough data, a spatial risk model, failure cases, and a plan that tests risky sources more often. | See it |
How the fingerprint decides
For each source, JalSatya keeps the mean and spread of six parameters from its own past results: conductivity, total hardness, chloride, alkalinity, iron and pH. A new result is scored by how far each value sits from that source's usual value, in units of its own spread, averaged across the six.
| Result | What it means | What happens |
|---|---|---|
| Matches its source | Score 2 or less. The water looks like this source's water. | Nothing. The result goes on for approval. |
| Looks like another source | Score 4 or more against its own source, and 2 or less against a different source within 15 km. | Flag to the AE with both sources on a map. A second sample is suggested. |
| One parameter off | Most parameters match; one is far out, for example iron much lower than usual. | Usually handling or the lab: iron settles out of a sample that wasn't preserved. The lab is asked to re-check. |
| Can't say | Shallow wells, ring wells and surface water swing with the seasons; sources with fewer than three past results. | No fingerprint verdict. These rely on location, custody and second samples. |
What it can't catch: two wells drawing from the same formation can look alike. The fingerprint catches the wrong kind of water, not necessarily the well next door. That's why the second sample exists. Thresholds are set on the pilot division's own history during the prototype phase.
How second samples are chosen
Random share
About 5% of routine samples each month, spread across teams and sub-divisions. Picked by the system, not by a person, and not shown to the original team.
Flagged samples
Any "looks like another source" result, and bottles whose two conductivity readings disagree.
Who goes
A different person: a neighbouring team, a mobile lab or the AE. Within a few days, so the water hasn't had time to change.
How it's read
Agreement rates by team and by lab over a year, shown with their sample sizes. Small numbers are labelled as small.
Risk, trends and limits
Risk map
A spatial model (we'd start with a random forest, the method used for India's published arsenic hazard maps) estimates for each source the chance that arsenic, fluoride or iron is above the limit. Inputs: location, depth, geology, distance from the river and neighbouring results.
What the model is for
Deciding where to test next, and testing new tube wells before commissioning. It never replaces a test, and a predicted risk is never shown to the public as a result.
Trends per source
A trend test (Mann-Kendall) only where a source has eight or more results. Below that, JalSatya shows the points and says "rising three times in a row", nothing more.
Limits
From IS 10500:2012, set by the Department: arsenic 0.01 mg/L, fluoride 1.0 mg/L (1.5 where there's no alternative source), nitrate 45 mg/L, E. coli not detectable. A PHED chemist confirms the full list.
The random-forest approach is from Podgorski et al. (2020), "Groundwater Arsenic Distribution in India by Machine Learning Geospatial Modeling". Arsenic in Assam is concentrated in the Brahmaputra floodplain; fluoride mainly around Nagaon, Hojai and Karbi Anglong (Mongabay, 2026, citing the Ministry of Jal Shakti). Both need checking against PHED's own data.
A routine sample
A flagged sample
A failed source
Light on the phone, careful in the lab
Roles, approvals, media capture and notifications already run in production in Vrixaa Connect, our live platform. JalSatya adds sampling, custody, the checks and the analytics. It can be hosted on the State Data Centre or a MeitY-empanelled cloud.
Access by role
A sampler sees their own list; a lab sees its bottles; a division sees its sources. Sign-in by OTP on registered phones.
Nothing is overwritten
Every reading, flag, exception and decision is kept with who, when and which device. A correction is a new version.
Hard to fake, honestly described
In-app photos only, network time, mock-location and rooted-phone checks. A copied QR plate still scans, which is why the water check exists.
Personal data
Staff names, phone numbers and the locations where they worked. Used only for sampling records, kept in India, handled under the DPDP Act 2023. No citizen data is collected.
What we'll settle with the Department in the first three weeks
The design rests on the challenge statement, the JJM water-quality guidelines and public information on Assam's laboratories and groundwater. These are the points we'll confirm with PHED's officers, chemists and samplers before building the production system.
- Who collects samples in the pilot division, how many sources each team covers, and how bottles reach the lab.
- Whether conductivity, hardness, chloride and alkalinity are recorded for every chemical sample, and for how many years.
- What WQMIS and LIMS export, and whether an upload format or API is available to the division.
- Who should take second samples, and what share the division can afford in field days.
- Permitted radius and block-or-flag choice for each kind of source, and the exception reasons PHED wants.
- Whether source coordinates and tube-well depths in the register are reliable enough for the risk model.