How it works

A record of every drinking-water sample, checked by where it was taken and by what's in it.

The sampler collects at the source, the lab tests the bottle, JalSatya compares the water with that source's own chemistry, and the division acts on anything that doesn't fit.

01In one minute

Four steps, three people

02What changes

Today, and with JalSatya

Today
With JalSatya
Proof of sampling
The sampler's entry in a register or app, and a supervisor's check.
Location inside the source's permitted area, plate scan and in-app photo, and then a check of the water against the source's chemistry.
The bottle on its way
A handwritten label. If it's swapped or mixed up, nobody can tell.
A QR bottle scanned at the source and at the lab, with conductivity read at both ends.
Cross-checking
A higher lab may re-test a share of the same bottles, where it has capacity.
About one sample in twenty is taken again at the source by a different person, unannounced.
GPS problems in the field
The rule is bent quietly, or the sample is lost.
The sampler asks for an exception with a reason. The AE decides, and the decision is kept with the sample.
Reading the history
One test at a time, in periodic reports.
Each source has a profile and every source has a risk estimate, so testing goes where the risk is.
After a failure
An alert, then it depends who follows up.
A case with steps, which closes only when a different team's sample passes.
03The challenge, point by point

What the Department asked for, and where to see it

The challenge asks forWhat JalSatya does
Geo-fencing / GPS or equivalent location verificationEach source has a permitted area. The phone must be inside it, with GPS accuracy shown. Mock-location apps are detected.See it
Secure source identificationA source ID from the JJM register, an optional QR plate, and the water's own fingerprint, which a copied plate can't fake.See it
Timestamping and field evidenceNetwork time, an in-app photo of the bottle at the source, and a pocket-meter conductivity reading.See it
Offline captureThe day's list and every sample are kept on the phone and sync when there's signal.See it
Chain-of-custody trackingQR bottles scanned at the source and at lab check-in, with time since collection and a second conductivity reading. No result without a check-in.See it
Configurable blocking or flagging outside the permitted areaThe AE sets, for each kind of source, the permitted radius and whether collection outside it is blocked or only flagged.See it
Auditable exceptions for genuine field or GPS constraintsReason codes, a note and an extra photo from the sampler; a decision with a reason from the AE. Kept with the sample for good.See it
GISA division map of sources with predicted arsenic, fluoride and iron risk, and which have never been tested.See it
Anomaly detectionThe fingerprint check on every result, conductivity at both ends, and second-sample agreement by team.See it
AI / analytics on historical results: recurring failures, seasonal trends, deterioration, emerging risksSource profiles with trends where there's enough data, a spatial risk model, failure cases, and a plan that tests risky sources more often.See it
Detailed breakdownFingerprint, second-sample and risk rules · Workflows · Architecture and security · Discovery
AThe rules

How the fingerprint decides

For each source, JalSatya keeps the mean and spread of six parameters from its own past results: conductivity, total hardness, chloride, alkalinity, iron and pH. A new result is scored by how far each value sits from that source's usual value, in units of its own spread, averaged across the six.

ResultWhat it meansWhat happens
Matches its sourceScore 2 or less. The water looks like this source's water.Nothing. The result goes on for approval.
Looks like another sourceScore 4 or more against its own source, and 2 or less against a different source within 15 km.Flag to the AE with both sources on a map. A second sample is suggested.
One parameter offMost parameters match; one is far out, for example iron much lower than usual.Usually handling or the lab: iron settles out of a sample that wasn't preserved. The lab is asked to re-check.
Can't sayShallow wells, ring wells and surface water swing with the seasons; sources with fewer than three past results.No fingerprint verdict. These rely on location, custody and second samples.

What it can't catch: two wells drawing from the same formation can look alike. The fingerprint catches the wrong kind of water, not necessarily the well next door. That's why the second sample exists. Thresholds are set on the pilot division's own history during the prototype phase.

How second samples are chosen

Random share

About 5% of routine samples each month, spread across teams and sub-divisions. Picked by the system, not by a person, and not shown to the original team.

Flagged samples

Any "looks like another source" result, and bottles whose two conductivity readings disagree.

Who goes

A different person: a neighbouring team, a mobile lab or the AE. Within a few days, so the water hasn't had time to change.

How it's read

Agreement rates by team and by lab over a year, shown with their sample sizes. Small numbers are labelled as small.

Risk, trends and limits

Risk map

A spatial model (we'd start with a random forest, the method used for India's published arsenic hazard maps) estimates for each source the chance that arsenic, fluoride or iron is above the limit. Inputs: location, depth, geology, distance from the river and neighbouring results.

What the model is for

Deciding where to test next, and testing new tube wells before commissioning. It never replaces a test, and a predicted risk is never shown to the public as a result.

Trends per source

A trend test (Mann-Kendall) only where a source has eight or more results. Below that, JalSatya shows the points and says "rising three times in a row", nothing more.

Limits

From IS 10500:2012, set by the Department: arsenic 0.01 mg/L, fluoride 1.0 mg/L (1.5 where there's no alternative source), nitrate 45 mg/L, E. coli not detectable. A PHED chemist confirms the full list.

The random-forest approach is from Podgorski et al. (2020), "Groundwater Arsenic Distribution in India by Machine Learning Geospatial Modeling". Arsenic in Assam is concentrated in the Brahmaputra floodplain; fluoride mainly around Nagaon, Hojai and Karbi Anglong (Mongabay, 2026, citing the Ministry of Jal Shakti). Both need checking against PHED's own data.

BThe workflows

A routine sample

Sampler
At the source
Inside the permitted area, plate scanned, bottle photographed, conductivity read. Saved offline.
Lab
Checks the bottle in
Scans it, notes the hours since collection, reads conductivity again.
Lab
Enters results
Typed in or imported from the instrument. Validated as they're entered.
JalSatya
Checks the water
Fingerprint against the source and its neighbours; limits; trend.
Lab in-charge
Approves
The result goes to WQMIS. A failure opens a case.

A flagged sample

JalSatya
Flags it
"Looks like Tihu Pub's tube well, 6 km away." The result is held, not published.
AE
Orders a second sample
Picks a different team. The original team isn't told.
Second sampler
Collects
Exactly like a routine sample, within a few days.
Lab
Tests it
Same checks as any other bottle.
AE
Decides
Which result stands, whether a case opens, and whether to talk to the team. JalSatya never decides this.

A failed source

JalSatya
Opens a case
On any result above the limit, after approval.
AE / JE
Acts
Users and Gaon Panchayat told, treatment checked, alternative supply noted.
Different team
Retests
Due within the days the Department sets.
JalSatya
Closes it
Only on a passing, verified result. "Days unsafe after detection" is tracked.
CArchitecture

Light on the phone, careful in the lab

Roles, approvals, media capture and notifications already run in production in Vrixaa Connect, our live platform. JalSatya adds sampling, custody, the checks and the analytics. It can be hosted on the State Data Centre or a MeitY-empanelled cloud.

People
Samplers
Lab chemists and in-charges
AE / EE, water quality
State water-quality cell
Apps
Android field appoffline, in-app camera, QR, pocket-meter entry
Lab web appcheck-in, results, instrument import
Division web app
Core
Source register & permitted areas
Custody & exceptions
Fingerprint & second-sample engine
Risk model & plan
Audit logappend-only
Data
PostgreSQL + PostGIS
Photo storage
Result history
Connects to
WQMIS / LIMSexport in, WQMIS format out; API if access is given
JJM source IDs
SMS gateway

Access by role

A sampler sees their own list; a lab sees its bottles; a division sees its sources. Sign-in by OTP on registered phones.

Nothing is overwritten

Every reading, flag, exception and decision is kept with who, when and which device. A correction is a new version.

Hard to fake, honestly described

In-app photos only, network time, mock-location and rooted-phone checks. A copied QR plate still scans, which is why the water check exists.

Personal data

Staff names, phone numbers and the locations where they worked. Used only for sampling records, kept in India, handled under the DPDP Act 2023. No citizen data is collected.

DDiscovery

What we'll settle with the Department in the first three weeks

The design rests on the challenge statement, the JJM water-quality guidelines and public information on Assam's laboratories and groundwater. These are the points we'll confirm with PHED's officers, chemists and samplers before building the production system.

  • Who collects samples in the pilot division, how many sources each team covers, and how bottles reach the lab.
  • Whether conductivity, hardness, chloride and alkalinity are recorded for every chemical sample, and for how many years.
  • What WQMIS and LIMS export, and whether an upload format or API is available to the division.
  • Who should take second samples, and what share the division can afford in field days.
  • Permitted radius and block-or-flag choice for each kind of source, and the exception reasons PHED wants.
  • Whether source coordinates and tube-well depths in the register are reliable enough for the risk model.