For the Public Health Engineering Department, Assam

Proof that the water in the bottle came from the source on the label.

A GPS fix and a photo show where the sampler stood. JalSatya also checks the water itself against the source's own chemistry. When something doesn't fit, a different person goes back for a second sample, unannounced. And a map of arsenic, fluoride and iron risk shows which sources need testing more often.

Uses tests labs already runconductivity, hardness, chloride
1 in 20 re-sampledby someone else, unannounced
Works with WQMIShistory in, results out
Water sample · bottle 26-1187Illustrative
Source
TW-0412 · Deep tube well, Borbhag
Collected
18 Nov 2026, 10:40
On the phone
✓ 14 m from source✓ plate scanned✓ photo
Does the water match its source?
Borbhag's usual rangeTihu Pub tube well, 6 km awayThis bottle
Every phone check passed, but the water matches a different tube well. Second sample ordered for this week.
01The problem today

One result a year decides whether a village keeps drinking from a tube well

PHED tests its sources in sub-divisional and district laboratories. Under the Jal Jeevan Mission guidelines, each source is tested for chemicals about once a year and for bacteria twice, before and after the monsoon. So a single bottle carries a lot of weight. If it's clean, the source stays in use for the next twelve months.

The Department lists four ways that bottle can be wrong, and says that today the proof rests mostly on what was written down and on supervisors' checks.

The wrong source

Two tube wells in one compound, or a tap instead of the well behind it. Nobody notices, because both are "Borbhag".

JalSatya: the water's chemistry is compared with that source's history, and its neighbours'.

The wrong place on the record

A location typed in later from memory, or a GPS fix that drifted under tree cover.

JalSatya: the phone has to be inside the source's permitted area, or the sample is blocked or flagged, as the Department chooses.

A substituted bottle

Filled at a nearer source, or labels swapped somewhere between the field and the bench.

JalSatya: conductivity read at the source and again at the lab, and a fingerprint check on every result.

An incomplete record

A missing time, a missing sampler, a bottle that arrived but has no paper.

JalSatya: the phone fills these in, and the lab can't enter a result for a bottle it never checked in.

Audits in other states show this is a real gap. CAG's 2026 audit of the Jal Jeevan Mission in Maharashtra (Report No. 2 of 2026) found water passed by a sub-divisional lab that was unfit when a fresh sample from the same source was tested at the district lab. It also found the 5% random cross-check by a higher lab was not being done. The once-a-year and twice-a-year testing norms are set in the Ministry of Jal Shakti's Drinking Water Quality Monitoring & Surveillance Framework (2021) and quoted in the same report. We haven't found an equivalent audit for Assam.

02Where things stand

Every sample is recorded in WQMIS. JalSatya adds a check from the water itself.

In place todayWhat it gives PHEDWhat JalSatya adds
WQMIS and LIMS (Jal Jeevan Mission)A unique ID for every sample, photographs, and an audit trail from collection to report.Each source's past results are read from WQMIS, and approved results go back with the same sample ID. Every new result is checked against the source's own chemistry.
Geotagging of official samples (JJM surveillance framework, 2021)Each sample is tied to the location of its source.The geofence, source plate and in-app photo are built in, with conductivity read at the source and again at lab check-in.
The 5% re-test by a higher lab (JJM guidelines)A second laboratory's opinion on a random share of samples.A fresh second sample from the source, taken by another team without notice, so the re-test also confirms where the water came from.

The geofence, the plate, the photo and offline capture are all part of JalSatya. The piece it adds is a witness that doesn't depend on the person holding the phone: the water.

Sources: WQMIS and LIMS as described by Vikaspedia (Ministry of Jal Shakti material). Mandatory geotagging and the 5% rule are in the Drinking Water Quality Monitoring & Surveillance Framework (2021); CAG quotes the 5% rule as para 10.1 of the JJM guidelines.

03What JalSatya does

Three ideas, one system

1 · The water's own fingerprint

Every source has its own chemistry. A bottle from somewhere else doesn't match.

A deep tube well's conductivity, hardness, chloride and alkalinity barely move from year to year. Labs already measure these on routine chemical samples. JalSatya keeps each source's usual range and checks every new result against it, and against the sources nearby.

The sampler can also read conductivity at the source with a pocket meter. The lab reads it again at check-in. If the two match, the bottle wasn't changed on the way. If both differ from the source's history, the water was different when it was filled.

At the source
322 µS/cm
pocket meter, 10:40
At the lab
318 µS/cm
check-in, 15:05
Borbhag usually
678–806
last 5 years
Same water at both ends, so the bottle wasn't swapped on the way.
Not Borbhag's water, so it was different when it was filled.
Conductivity for bottle 26-1187 (synthetic). The full check uses six parameters.
2 · A second sample, unannounced

About one sample in twenty is taken again, by someone else.

JalSatya picks a random share of samples, plus any the fingerprint flags, and sends a different person back to the same source within a few days, without notice. It's the guidelines' 5% cross-check moved from the lab bench to the source.

Most second samples agree, and that's the point: it builds confidence in the routine results. Where a team's results disagree more often, the division knows where to look. It's quality assurance, read as a pattern, never as a verdict on one person.

First sample
Second sample
Taken
18 Nov, routine
26 Nov, another team
Conductivity
318 µS/cm
748 µS/cm
Matches Borbhag
No
Yes
Arsenic
0.003 mg/L
0.012 mg/L

The limit is 0.01 mg/L. The first sample would have cleared a well that is above it.

Synthetic example. It's the flow you can click through in the prototype.
3 · A risk map that knows the geology

Arsenic, fluoride and iron follow the rocks. The plan should too.

With one chemical test a year, a single source's history is too short to forecast. A division's history is not. JalSatya estimates the arsenic, fluoride and iron risk of every source, including ones never tested, from its depth, the geology and its neighbours' results. Sources with high risk and little testing move up the plan, and a new tube well is tested before it's commissioned.

Every failed result opens a case: users told, an alternative noted, a retest by a different team. The case closes only when a verified sample passes.

HighMediumLowNever tested
Predicted arsenic risk for one synthetic division. A model's estimate, never a substitute for a test.
04Fits what you have

Built around PHED's existing systems

  • WQMIS stays the recordPast results come in from WQMIS and LIMS exports. Approved results go back in WQMIS's own format, with the same sample IDs. Nobody types a result twice.
  • PHED's laboratories keep their methodsThe fingerprint uses parameters the district and sub-divisional labs already measure. No new test.
  • Mobile labs and nearby teams take second samplesA mobile lab, a neighbouring sub-division's team or the AE, whichever the division prefers.
  • Field test kits feed the planA positive community kit result puts that source on the next lab sampling plan, with the reason attached.
  • Sources keep their JJM IDsScheme codes and source IDs stay as they are. JalSatya adds a permitted area, a depth and a fingerprint.
  • Limits come from IS 10500Set by the Department, not hard-coded, and confirmed by a PHED chemist before the pilot.